May 3, 2024
Journal Article
Biocompatible Co-P Metallic Glasses with Superior Degradation Tolerance in Physiological Environment
Abstract
Metallic glasses represent a class of metallic alloys with a fully amorphous structure and attractive properties, making them promising in bioimplant applications. Here, the degradation tolerance of biocompatible cobalt–phosphorus (Co–P) metallic glasses was studied in a simulated physiological environment. The metallic glasses were synthesized in the form of coatings through a facile electrodeposition approach. This method utilizes their outstanding surface characteristics and bypasses the size limitations usually associated with their bulk counterparts. The Co–P alloys showed exceptional tribological response with ~14% lower coefficient of friction and 2 orders of magnitude lesser wear rate compared to SS316 stainless steel. In addition, the Co–P alloys showed a 3 times higher hardness and 4 times higher hardness/modulus ratio compared to SS316, indicating better elastic recovery under dynamic shear stresses that are common in load-bearing bioimplants. The Co–P metallic glasses exhibited excellent hemocompatibility and cytocompatibility in terms of lower platelet adhesion, spreading, and aggregation, a hemolysis ratio lower than 1%, and enhanced surface wettability, suggesting a superlative performance in bioimplant applications.Published: May 3, 2024